Materials testing: what it is, types, destructive and non-destructive testing, standards and how to choose

Materials testing is the standardized procedure that measures the mechanical, physical, chemical or microstructural properties of a representative sample, or that inspects a part without damaging it. See the five families of tests, the difference between destructive and non-destructive testing, the test specimen, accreditation, the standards and how to choose the right test.

Mechanical TestingBy Mardoqueu M. Costa25 min read

Materials testing is the standardized procedure that measures the mechanical, physical, chemical or microstructural properties of a representative sample, or inspects a part without damaging it, in order to qualify the material, control quality, develop products and investigate failures. The result is a number or an accept/reject decision, obtained with the procedure of a standard and compared with the material or product specification.

Tests fall into five families: mechanical, non-destructive, metallographic, chemical, and physical or thermal. There is no single materials testing formula: each method has its own quantities and its own standard. This guide shows what each family measures, the difference between destructive and non-destructive testing, how the sample and the machine calibration decide whether the result is valid, a table that links the engineering question to the right test, and two practical cases, one of incoming lot inspection and one of failure analysis.

The photo shows the best-known test of the mechanical family being set up: the tensile test specimen is already clamped in the grips of the universal testing machine, and the extensometer, the sensor with thin arms resting on the central section, will measure the elongation directly on the material.

Hand positioning a tensile test specimen in the grips of a universal testing machine, with an extensometer attached to the specimen
Tensile test specimen in the grips of the universal testing machine, with the extensometer attached to the gauge section

What materials testing is and what it is for

Testing means determining a characteristic of a material, component or product by following a defined procedure under controlled conditions. The key word is defined: the test standard sets the sample geometry, temperature, speed, equipment and calculation. Only then do two laboratories get the same number for the same material, and only then can the number be compared with a specification minimum. ISO/IEC 17025:2017 (ABNT NBR ISO/IEC 17025 in Brazil), which covers the competence of laboratories, starts from exactly this idea: testing is the technical activity of the laboratory, and what is assessed is whether it is performed in a reproducible and traceable way.

The test can be performed on a test specimen, which is a sample with a geometry defined by the standard, on a complete part or on a prototype. Some tests destroy the sample to measure a limit, such as the tensile test, which takes the specimen to fracture; others examine the part and return it to service, such as ultrasonic testing. This difference, which organizes much of the field, is covered in its own section further on.

"Ensaio" and "teste": what is the difference

In Brazilian technical Portuguese, ensaio is the standardized procedure, with a measurable and traceable result, that can go into a test report. Teste is the colloquial term and usually refers to a functional, pass/fail check: switching on a machine to see if it works is a "teste"; pulling a specimen to ISO 6892-1 (ABNT NBR ISO 6892-1:2024 in Brazil) and calculating its strength is an "ensaio". In English both ideas use the same word, test, which is where the confusion in translations comes from. No Brazilian standard defines "teste" as a technical term; method standards use "ensaio".

The five purposes of testing

The same methods serve different goals, and the goal changes how many samples are tested and how rigorously:

  1. Qualification and approval: approving a material, a supplier or a process, such as a welding procedure, before it goes into production.
  2. Quality control: at receiving inspection and in production, lot by lot, according to the product standard, which states which tests to perform and which minimums to meet.
  3. Research and development: characterizing a new material or measuring the effect of a heat treatment.
  4. Failure analysis: finding out why a part broke in service, which usually combines several test families.
  5. Certification and compliance: issuing a report from an accredited laboratory or a material certificate for a customer, a public tender or a regulatory body.

Types of materials testing: the five families

The most useful way to classify tests is by what they measure. Mechanical tests measure the response to a force: strength, stiffness, ductility, hardness, toughness. Non-destructive tests (NDT) look for discontinuities, such as cracks, pores and inclusions, without compromising the part. Metallographic tests reveal the structure of the metal on a cut and prepared section. Chemical tests determine composition. Physical and thermal tests measure density, thermal expansion and the transitions the material undergoes when heated.

A second way to classify, which crosses the first, is by the damage the test causes. The diagram below combines both: each row is what is measured and each column is how much the sample suffers. NDT methods alone occupy the "no damage" corner, hardness and spectrometry leave only a local mark, and most mechanical, metallographic and thermal tests consume the sample.

Diagram of the materials testing families on a grid: the horizontal axis shows damage to the sample (none, local mark, destroys the sample) and the vertical axis shows what is measured (defect, microstructure, composition, physical or thermal property, mechanical property). Non-destructive tests sit at no damage and defect; hardness and spectrometry at local mark; tensile, impact, fatigue, metallography, DSC and TGA at destroys the sample
Map of the testing families: what each one measures and how much damage it causes to the sample (qualitative diagram)

The column position determines the control strategy. What sits in the left column can be applied to every part produced; what sits in the right column can only be done by sampling, on sacrificed parts or specimens that represent the lot. The table summarizes the families, and the methods of each are described in the following sections:

FamilyWhat it measuresTypical methodsDamage to the sample
Mechanicalresponse to force: strength, stiffness, ductility, hardness, toughnesstensile, compression, flexural, hardness, impact, fatiguelocal mark (hardness) or fracture
Non-destructivediscontinuities and thicknessvisual, liquid penetrant, magnetic particle, ultrasonic, radiography, eddy currentnone
Metallographicmacro- and microstructure: phases, grain, inclusions, layersmacrography, micrographysample is cut
Chemicalchemical compositionoptical emission spectrometry, combustionlocal mark or sample consumed
Physical and thermaldensity, thermal expansion, thermal transitions, mass lossdensity, dilatometry, DSC, TGAusually, a small sample is consumed

Mechanical tests

Mechanical tests apply a controlled load and record the material's response. The main ones are the tensile, compression, flexural, bend, shear, torsion, cupping, hardness, impact, fatigue and creep tests. By loading rate, they are divided into quasi-static tests, in which the force increases slowly (tensile, compression, flexural), dynamic or impact tests, in which the load is applied in a single blow (Charpy), and cyclic tests, in which the load is repeated millions of times (fatigue).

The tensile test is the most widely used to characterize metals because, on its own, it gives the yield strength, the ultimate tensile strength, the elongation and, with an extensometer, the modulus of elasticity. Each mechanical test has its own article, and the guide to the main mechanical tests brings them all together, with what each one measures, the standard and the machine. The quantities they measure are covered in the article on the mechanical properties of materials.

Non-destructive tests

Non-destructive testing (NDT) is the examination that evaluates a part without impairing its later use; the terminology of the field is in ASTM E1316. NDT finds and sizes discontinuities, or measures thickness, and can therefore be applied to 100% of parts, including equipment in operation. Each method is based on a different physical phenomenon, and each phenomenon imposes a limit: no method works for everything. The six most widely used, from the simplest to the most elaborate:

  • Visual: always the first. It requires good lighting and access to the surface, and may use a magnifier, mirror or camera. For welds, the procedure is in ISO 17637. It only sees what reaches the surface.
  • Liquid penetrant: a low-viscosity liquid, red or fluorescent, enters the discontinuities by capillary action; after the excess is removed, a developer draws the liquid back to the surface and marks the crack. It only finds discontinuities open to the surface and does not work on porous material (ASTM E165/E165M).
  • Magnetic particle: the part is magnetized, and a crack distorts the field and gathers the iron particles applied dry or in suspension. It detects surface and near-surface discontinuities, but only in ferromagnetic material: it does not work on austenitic stainless steel, aluminum or copper (ASTM E709). The part is demagnetized at the end.
  • Ultrasonic: a probe emits high-frequency mechanical waves, which reflect off the back wall and off any internal discontinuity. It detects volumetric defects and measures thickness with access from one side only (ASTM E797/E797M, contact pulse-echo). It requires couplant between the probe and the part and a qualified operator to interpret the echoes.
  • Radiography: X-rays or gamma rays pass through the part and record differences in thickness and density on film or a digital detector. It is volumetric and leaves a permanent record, which makes it common for welds and castings (ASTM E1742/E1742M). It requires radiation protection.
  • Eddy current: a coil induces electric currents in the part, and surface cracks or variations in conductivity or coating thickness alter these currents (García-Martín, Gómez-Gil and Vázquez-Sánchez, Sensors, 2011). It only works on conductive material and is widely used on tubes (ASTM E426).

Other methods, such as acoustic emission, thermography and leak testing, complete the list, especially for composites, where ultrasonic testing and thermography are the most studied (Gholizadeh, Procedia Structural Integrity, 2016).

Two points are often misunderstood. First, NDT does not measure strength: it tells whether there is a crack and how large it is, but it does not give the ultimate tensile strength or the toughness. Second, the result depends on who performs it. That is why NDT personnel are certified by method and by level under ISO 9712:2021 (adopted in Brazil, identically, as ABNT NBR NM ISO 9712:2025). In Brazil, certification is carried out by ABENDI (the Brazilian Association of Non-Destructive Testing and Inspection), a body accredited by Inmetro (Brazil's national metrology and accreditation institute) for certification of persons under ISO/IEC 17024 (ABNT NBR ISO/IEC 17024).

Metallographic tests

Metallography examines the structure of the metal on a prepared section, and it is what explains why two parts made of the same steel have different properties. It works at two levels of magnification.

Macrography is performed on a ground and chemically etched section, observed with the naked eye or at low magnification. It shows segregation, the grain flow of a forged part, the zones of a weld and coarse porosity (ASTM E340). Micrography uses the microscope and follows a fixed sequence: cutting, mounting in resin, grinding with progressively finer grit, polishing to a mirror finish and chemical etching, which reveals grain boundaries and phases (ASTM E3 for preparation and ASTM E407 for etching). Under the microscope you see the phases, such as ferrite, pearlite and martensite, the inclusions, the case of a carburized part and the grain size, measured to ASTM E112.

Because it requires cutting, metallography is destructive for the sample. It is the link between process and property: micrography confirms whether a heat treatment produced the expected structure, whether the case of a carburizing treatment has the required depth, or whether the grains are elongated by work hardening. Each step has its own equipment: the metallographic cutting machine cuts the sample without heating it enough to alter the structure, the metallographic grinding and polishing machine performs grinding and polishing with speed and pressure control, and the metallurgical microscope performs the microstructural analysis.

Chemical tests

Chemical testing answers a simple and decisive question: is the material what the certificate says it is? For steels, the most widely used method is spark optical emission spectrometry (OES): a spark vaporizes a spot on the surface, and the light emitted by each element is separated and measured. ASTM E415 uses this to determine 21 alloying and residual elements simultaneously in carbon and low-alloy steels. The sample needs a flat face that seals the opening of the spectrometer stand, and the spark leaves only a small burn mark.

For more accurate carbon and sulfur values, chips of the sample are burned in an induction furnace and the gases are analyzed. Chemical methods are the first step when a part behaves poorly and a material mix-up is suspected.

Physical and thermal tests

This family measures properties that do not depend on force and that matter mainly for polymers, ceramics and composites:

  • Density: by immersion, using Archimedes' principle; it reveals porosity and confirms the identity of plastics.
  • Dilatometry: measures the coefficient of linear thermal expansion with a push-rod dilatometer (ASTM E228).
  • DSC (differential scanning calorimetry): measures the heat absorbed or released on heating, which gives the glass transition, melting, crystallization and cure of polymers (ISO 11357-1:2023).
  • TGA (thermogravimetric analysis): measures mass loss with temperature, typically from room temperature to 1,000 °C, and with it the volatile, filler and ash content (ASTM E1131).
  • Electrical and thermal conductivity: complete the characterization when the part conducts current or heat.

Destructive and non-destructive tests

A destructive test renders the sample unusable, or deforms it so much that it cannot return to service, and in return measures a limit of the material: how much it can withstand, how much energy it absorbs, what its exact composition is. A non-destructive test keeps the part fit for use and in return only finds defects. One does not replace the other: destructive testing qualifies the material and the process by sampling, and NDT checks every part produced. The table compares the two:

CriterionDestructiveNon-destructive (NDT)
The part after the testfractured, cut or deformed; does not return to serviceintact, fit for use
What it measuresproperties: strength, toughness, composition, microstructurediscontinuities and thickness
How many partssamples per lotup to 100% of parts, including in service
Examplestensile, impact, fatigue, micrography, combustionvisual, liquid penetrant, magnetic particle, ultrasonic, radiography, eddy current
Referencethe standard for each method, such as ISO 6892-1 (ABNT NBR ISO 6892-1:2024 in Brazil)ASTM E1316 (terms) and ISO 9712 (ABNT NBR NM ISO 9712 in Brazil) (personnel)

Hardness is the borderline case. The indenter leaves only a small impression, and Callister and Rethwisch (Materials Science and Engineering, 10th ed., ch. 6) describe it as a relatively non-destructive test, because the part neither fractures nor deforms appreciably. Even so, hardness is not an NDT method under ISO 9712, and the mark can cause a polished functional surface to be rejected. The guide to mechanical tests discusses this classification, and the article on the hardness test gives the minimum thickness each method requires.

Test specimen, sampling and reliability of results

A perfect test on the wrong sample, in an uncalibrated machine, produces a worthless number. Three conditions make a result reliable: the sample represents the lot, the instrument measures correctly and the laboratory demonstrates competence.

Sample and test specimen

A destructive test does not measure the lot; it measures the sample, so the sample must represent the lot. ISO 377:2017 sets out the identification, location and preparation of samples and test specimens for mechanical testing of steel sections, bars, wire rod, flat products and tubes. Position matters: in a thick bar, the core cooled more slowly than the surface and has a different microstructure, and in a rolled plate the longitudinal direction gives a different result from the transverse direction. When the product standard specifies position and direction, it takes precedence.

Once taken, the sample is machined into a test specimen with the geometry required by the test standard, such as ABNT NBR ISO 6892-1:2024 (the Brazilian adoption of ISO 6892-1) or ASTM E8/E8M for tensile testing of metals. Machining must be done carefully: overheating the material during cutting or turning alters its microstructure and, with it, the result.

Calibrated machine

The force measured by the machine must be traceable to a standard. ABNT NBR ISO 7500-1:2023, equivalent to ISO 7500-1:2018, verifies the force-measuring system with a reference instrument and classifies the machine into classes 0.5, 1, 2 and 3. The main criterion is the relative accuracy error, q = (Fi − F) / F × 100, where Fi is the force indicated by the machine and F is the reference force; in each class, |q| must not exceed the class number, in %. In class 1, therefore, the permitted error is ±1.0%. ASTM E4, used in the United States, adopts a criterion of ±1% of the applied force, without a ladder of classes.

An example: with a reference force of 50.00 kN, the machine indicates 50.30 kN. Then q = (50.30 − 50.00) / 50.00 × 100 = +0.60%. The machine passes class 1 (±1.0%) and fails class 0.5 (±0.5%). Most test standards require class 1 or better, and verification is repeated periodically and always after a repair, a load cell replacement or a relocation of the machine.

Accredited laboratory and certified personnel

ABNT NBR ISO/IEC 17025:2017 (the Brazilian adoption of ISO/IEC 17025) sets out the requirements for competence, impartiality and consistent operation of testing and calibration laboratories. In Brazil, laboratories are assessed and accredited by Cgcre, the accreditation body of Inmetro (Brazil's metrology institute): accredited testing laboratories form the RBLE (Brazilian Network of Testing Laboratories), calibration laboratories form the RBC (Brazilian Calibration Network), and the listings are public. Three different certifications are often confused: laboratory accreditation (ISO/IEC 17025), certification of persons, such as NDT inspectors (ISO/IEC 17024 and ISO 9712), and product certification, which attests that a product complies with its standard.

How to choose the test

The starting point is not the equipment available but the engineering question. When a product standard exists (for a rebar, a tube, a structural section), it already states which tests to perform and which values to meet. When it does not, as in an investigation or a development project, the table below links the most common questions to the test that answers them:

QuestionTestReference standard
What are the strength and ductility?tensile testABNT NBR ISO 6892-1:2024, ASTM E8/E8M
Is there a surface crack?liquid penetrant; magnetic particle if ferromagneticASTM E165/E165M; ASTM E709
Is there an internal defect?ultrasonic or radiographic testingASTM E797/E797M; ASTM E1742/E1742M
Is the steel the specified grade?optical emission spectrometryASTM E415
Was the heat treatment done right?micrography and hardness profileASTM E3, ASTM E407; hardness test
Does it withstand impact at low temperature?Charpy impact testASTM E23, ISO 148-1
Does it withstand repeated loading?fatigue testmaterial or component standard
At what temperature does the polymer soften?DSCISO 11357-1:2023

Two rules complete the table. Choose a method compatible with the material, because magnetic particle testing does not work on austenitic stainless steel and eddy current testing does not work on insulating materials. And when the sample is unique, as with a failed part, start with the least destructive method, so as not to lose evidence that a later test would need.

Two practical cases

The two cases show how the test families combine. The numbers are illustrative and hypothetical: they do not correspond to a specific steel grade.

Case 1: accepting or rejecting a lot of bars

A lot of round steel bars arrives with the supplier's certificate, and the purchase specification, hypothetical, requires Rm of at least 520 MPa and elongation of at least 20%. The test plan checks the certificate in four steps:

  1. Composition: optical emission spectrometry (ASTM E415) to confirm that the grade matches the certificate.
  2. Hardness screening: the bar measures 168 HB. For steels, Callister and Rethwisch give the approximate correlation Rm (MPa) ≈ 3.45 × HB, so Rm ≈ 3.45 × 168 ≈ 580 MPa. This is only an estimate, indicating that it is worth proceeding; it does not replace the tensile test in the report.
  3. Tensile test: test specimen taken according to ISO 377 and tested to ABNT NBR ISO 6892-1:2024, with diameter d0 = 10.0 mm.
  4. Micrography: only if the specification calls for grain size (ASTM E112).

The tensile calculation starts from the cross-sectional area, S0 = π × 10.0² / 4 = 78.54 mm². For a proportional test specimen, the gauge length is L0 = 5.65 × √S0 = 5.65 × 8.862 = 50.07 mm, rounded to 50 mm. The machine records a maximum force Fm = 45.6 kN, and the final length between the marks, fitting the two fractured halves together, is Lu = 61.5 mm:

  • Tensile strength: Rm = Fm / S0 = 45,600 / 78.54 = 580.6 MPa, above 520 MPa and consistent with the hardness-based estimate.
  • Elongation after fracture: A = (Lu − L0) / L0 × 100 = (61.5 − 50) / 50 × 100 = 23.0%, above 20%.

With the composition confirmed and both tensile requirements met, the lot is accepted. The article on the tensile test details yielding, test speed and how to read the curve.

Case 2: investigating a broken shaft

A shaft fractured in service, and there is only one broken part. The rule is the one from the previous section: start with what does not destroy and move on to what cuts and breaks, preserving the evidence. The sequence below shows the seven typical stages, with the family of each and the increasing damage bar underneath:

Seven-stage sequence of a shaft failure analysis: visual inspection, non-destructive testing of sister parts, macrography, micrography, microhardness profile, chemical analysis and tensile test, with a damage bar increasing from intact part to cut and fractured part
Failure analysis in seven stages, from the method that leaves the part intact to the one that cuts and breaks it
  1. Visual inspection and photography of the fracture. Concentric beach marks radiating from a single point indicate a crack that grew gradually, typical of fatigue.
  2. NDT on sister parts still in service, by magnetic particle testing if the steel is ferromagnetic, to find cracks before another part fails.
  3. Macrography of a section, to see the grain flow, the crack origin and any manufacturing defects.
  4. Micrography to check the microstructure and the depth of the hardened case.
  5. Microhardness profile on the same sample, from the surface to the core; the procedure is in the article on the hardness test.
  6. Chemical analysis to find out whether the material was the specified one.
  7. Tensile test on a test specimen taken from the part itself, if there is enough material.

Failure analysis is the case in which all five families work together, and it is also the best argument in favor of incoming inspection testing: many of the failures investigated this way end up traced to a material, a heat treatment or a case layer that a lot test would have rejected.

Materials testing standards

The product standard decides which tests are mandatory; the method standards say how to perform each one. The table lists the standards cited in this article, by family, with the current edition checked in September 2026:

FamilyStandardScopeEdition
GeneralABNT NBR ISO/IEC 17025competence of testing and calibration laboratories2017
GeneralISO/IEC 17025competence of testing and calibration laboratories2017
GeneralISO 377location and preparation of steel samples and test specimens2017 (confirmed in 2022)
GeneralABNT NBR ISO 7500-1force verification of tension and compression testing machines2023
GeneralISO 7500-1force verification of tension and compression testing machines2018
GeneralASTM E4force calibration and verification of testing machinesE4-24
MechanicalABNT NBR ISO 6892-1tensile testing of metals at room temperature2024
MechanicalASTM E8/E8Mtensile testing of metalsE8/E8M-25
NDTASTM E1316terminology for nondestructive examinationsE1316-26c
NDTABNT NBR NM ISO 9712qualification and certification of NDT personnel2025
NDTISO 9712qualification and certification of NDT personnel2021
NDTISO 17637visual testing of fusion-welded joints2016
NDTASTM E165/E165Mliquid penetrant testing, general industryE165/E165M-23
NDTASTM E709guide for magnetic particle testingE709-21
NDTASTM E797/E797Mthickness measurement by manual contact pulse-echo ultrasonic methodE797/E797M-21
NDTASTM E1742/E1742Mradiographic examinationE1742/E1742M-23
NDTASTM E426eddy current testing of seamless and welded tubesE426-16(2021)
MetallographicASTM E3preparation of metallographic specimensE3-26
MetallographicASTM E340macroetching of metals and alloysE340-23
MetallographicASTM E407microetching of metals and alloysE407-23
MetallographicASTM E112average grain sizeE112-25e1
ChemicalASTM E415carbon and low-alloy steel by spark atomic emission spectrometryE415-21
Physical and thermalASTM E228linear thermal expansion with a push-rod dilatometerE228-22
Physical and thermalISO 11357-1DSC of plastics, general principles2023
Physical and thermalASTM E1131compositional analysis by thermogravimetryE1131-25

The hardness, impact and fatigue standards are covered in the article on each test, starting from the guide to mechanical tests.

Biopdi equipment for materials testing

Biopdi manufactures equipment for two of the five families. For mechanical testing, the M2 line universal testing machine comes in 15 capacities, from 200 N to 1,000 kN, with class 1 force measurement according to ABNT NBR ISO 7500-1:2023. In it, the load cell measures force, the extensometer measures strain over the gauge length, and the BioLab software converts the force × displacement curve into stress × strain and issues the report. By changing grips and fixtures, the same machine performs tensile, compression, flexural, shear, cupping, pull-out and bond tests, and torsion and dynamic modules are available on request; how it works is explained in the article on the universal testing machine. For repeated loading, there is mechanical cycling.

In metallography, Biopdi manufactures the cutting machine, the grinding and polishing machine and the metallurgical microscope mentioned in the metallography section, which cover sample preparation and analysis. And beyond metals, the soil testing equipment, such as triaxial, CBR and Marshall, consolidation and direct shear, shows that materials testing also applies to soils and asphalt mixtures.

Other tests and technical references

Related technical references

Frequently asked questions

What are the types of materials testing?

There are five families: mechanical (tensile, compression, flexural, hardness, impact, fatigue), non-destructive (visual, liquid penetrant, magnetic particle, ultrasonic, radiographic, eddy current), metallographic (macrography and micrography), chemical (optical emission spectrometry, combustion analysis) and physical or thermal (density, dilatometry, DSC, TGA). By the damage they cause, tests are also divided into destructive and non-destructive.

What are the test methods?

Each family has standardized methods, and each method has its own standard. Examples: tensile testing of metals per ISO 6892-1:2024 (ABNT NBR ISO 6892-1 in Brazil), ultrasonic thickness measurement per ASTM E797/E797M, metallographic preparation and etching per ASTM E3 and E407, composition of steels per ASTM E415 and thermal transitions of polymers per ISO 11357-1:2023. The product standard states which of these methods are mandatory.

What is the difference between "ensaio" and "teste"?

In Portuguese, "ensaio" is the standardized procedure, with a measurable and traceable result that can go into a test report, such as the tensile test of a specimen per ABNT NBR ISO 6892-1:2024. "Teste" is the colloquial term, usually for a pass/fail functional check. In English both ideas are "test", which explains the confusion in translations.

What is the difference between destructive and non-destructive testing?

Destructive testing renders the sample unusable or deforms it and, in return, measures properties such as strength, toughness and composition; that is why it is done by sampling, lot by lot. Non-destructive testing keeps the part in usable condition and looks for discontinuities, so it can be applied to every part, including parts in service. The two complement each other: one qualifies the material, the other checks each part.

What are the non-destructive tests?

The six most widely used are visual, liquid penetrant (ASTM E165/E165M), magnetic particle (ASTM E709), ultrasonic (ASTM E797/E797M), radiographic (ASTM E1742/E1742M) and eddy current (ASTM E426) testing. Acoustic emission, thermography and leak testing complete the list. Inspectors are certified per ABNT NBR NM ISO 9712 (the Brazilian adoption of ISO 9712).

Is the hardness test destructive?

It sits on the borderline. It leaves only a small indentation, and Callister and Rethwisch describe it as relatively non-destructive. But it is not an NDT method under ISO 9712, and the mark can cause a functional surface to be rejected, so it does not replace non-destructive inspection.

What is metallographic testing?

It is the examination of the metal's structure on a prepared section. Macrography uses an etched section, viewed with the naked eye or at low magnification (ASTM E340). Micrography uses a microscope after cutting, mounting, grinding, polishing and etching (ASTM E3 and E407), and reveals phases, inclusions, layers and grain size.

What is a test specimen?

It is the sample with geometry and preparation defined by the test standard, taken from a specific location in the product. For steel products, ISO 377:2017 defines where and how to take the sample; the geometry comes from the test standard, such as ABNT NBR ISO 6892-1:2024 for tensile testing.

What is an accredited laboratory?

In Brazil, it is a laboratory whose competence has been recognized by Cgcre/Inmetro (the Brazilian accreditation body) according to ABNT NBR ISO/IEC 17025:2017 (the Brazilian adoption of ISO/IEC 17025). Accredited testing laboratories form the RBLE (Brazilian Network of Testing Laboratories), calibration laboratories form the RBC (Brazilian Calibration Network), and the list is public.

Why does the testing machine need to be calibrated?

Because without force traceability the result is not valid for qualification. ISO 7500-1:2023 (ABNT NBR ISO 7500-1 in Brazil) classifies the machine into classes 0.5, 1, 2 and 3; in class 1, the permitted accuracy error is ±1.0%. Verification is repeated periodically and after a repair, a load cell replacement or a change of location.

Which standards govern materials testing?

Each method has its own: ABNT NBR ISO 6892-1:2024 for tensile testing of metals, ASTM E415 for composition of steels, ASTM E3 for metallographic preparation, ISO 11357-1:2023 for DSC, among others. The product standard is what defines which tests are required and the minimum values.

Talk to a Biopdi specialist

Tell us the test you need to run and the standard you need to meet.